Description
The module is designed for both military and commercial applications. The latest device technologies and design methods are employed to offer high power density, efficiency, and linearity in a small, lightweight package.
Specification
Typical performance at +28 VDC +25oC, and in a 50Ω system.
RF / ELECTRICAL | |||||
PARAMETER | MIN | TYP. | MAX | UNIT | |
RF Frequency | 10700 | 12700 | MHz | ||
RF INPUT | 0 | dBm | |||
P-sat Power Output | 50 | dBm | |||
Power Gain | 50 | dB | |||
Power Gain Flatness | ±1 | dB | |||
Temperature-induced gain variation | ±1 | dB | |||
IM3@Return of rated power 6dB ,The interval between two tone signals is 10MHz | -25 | dBc | |||
Input VSWR | 1.5 | — | |||
Output VSWR | Build-in Isolator for VSWR protection | — | |||
Spurious Signals | -55 | dBc | |||
Power consumption | @saturation | 600 | W | ||
@linear | 500 | W | |||
Operating Voltage | 24 | 28 | 30 | V DC | |
In-Out impedance | 50 | Ω | |||
MECHANICAL | ||
PARAMETER | VALUE | UNIT |
Dimensions (L x W x H) | 450*336 * 139mm | mm |
RF Connectors (Input / Output) | N- KFD/ Waveguide WR75 | — |
Cooling | Consider heat dissipation with the system | — |
Mounting | φ4.5-6 Thru Hole | — |
Weight | ≤15 | kg |
ENVIRONMENTAL / PROTECTIONS | |||
PARAMETER | MIN | MAX | UNIT |
Operating Temp. (Housing Temp.) | -20 | +60 | °C |
Humidity Range | 0-95 | % | |
Protections | Open circuit/short circuit/ over temperature protection | — | |
Monitoring interface for temperature, tx power and errors | — | ||