Description
The module is designed for both military and commercial applications. The latest device technologies and design methods are employed to offer high power density, efficiency, and linearity in a small, lightweight package.
Specification
Typical performance at +36V DC +25oC, and in a 50Ω system.
RF / ELECTRICAL | ||||
PARAMETER | MIN | TYP. | MAX | UNIT |
Operating Frequency | 2700 | 3000 | MHz | |
Operation mode | Pulsed | –– | ||
RF INPUT | 35 | 36 | 37 | dBm |
Power Gain | 24 | dB | ||
P-sat Output Power (Pulsed) | 60 | dBm | ||
Power Gain Flatness | ±2 | dB | ||
Pulse width | 100 | us | ||
Duty cycle | 10 | % | ||
In/Out Impedance | 50 | Ω | ||
Input VSWR | -10 | dB | ||
Spurious Signals | -55 | dBc | ||
Harmonic Signals | -20 | dBc | ||
Operating Voltage | 31 | 36 | 40 | V DC |
Power consumption@ Average | 500 | W | ||
MECHANICAL | ||
PARAMETER | VALUE | UNIT |
Dimensions (W x D x H) | 605×228×55 | mm |
RF Connectors (Input / Output) | SMA-KF / N-K | — |
Control Connector | K20-B9:Power on/power off control | — |
DC Connectors | K20- B2 | –– |
Cooling | External Heatsink Required | — |
Weight | ≤5 | kg |
ENVIRONMENTAL / PROTECTIONS | |||
PARAMETER | MIN | MAX | UNIT |
Operating Temp. | -20 | +65 | °C |
Protections | With over temperature protection/ over input protection /Overvoltage and under voltage protection | –– | |
Phase adjustment | Reserved phase adjustment function | –– | |
INPUT/OUTPUT panel Connector | |||
AMPLIFIER CONNECTOR TYPE: | —— | ||
TRIAD CABLE PART NUMBER: | —— | ||
NUMBER | interface type | DESCRIPTION | |
X1 | SMA-K | RF IN | |
X2 | N-K | RF OUT | |
X3 | K20-B9 | Control interface | |
X4 | K20- B2 | DC power socket | |
Connector Definition | ||
AMPLIFIER CONNECTOR TYPE: | K20-B9 | |
TRIAD CABLE PART NUMBER: | —— | |
NUMBER | Definition | DESCRIPTION |
1 | NC | NC |
2 | GND | GND |
3 | +5V | +5V (from outside) |
4 | -5V | -5V(from outside) |
5 | OUT(+VE) | OUT(+VE) |
6 | NC | NC |
7 | OUT(-VE) | OUT(-VE) |